One Check Fire — Compartmentation
Fire Door Inspections
Inspections to BS 8214:2026 keeping compartmentation intact and escape routes protected.
Back to One Check Fire
Overview
Fire doors are the first line of defence in compartmentation, slowing the spread of smoke and flame long enough for occupants to escape. Our inspectors assess every leaf against BS 8214:2026 and the requirements of the Regulatory Reform (Fire Safety) Order, checking gaps, seals, closers, glazing and hardware, and delivering a clear report with photographs and prioritised actions.
Since the fire door failures highlighted after the Grenfell Tower Inquiry, building owners and responsible persons face much closer scrutiny of their fire doors. A documented, competent inspection is now the expected evidence that doors have been assessed by someone qualified, not simply walked past. We provide that evidence on every leaf, with a record your responsible person can hand to inspectors and insurers.
What we do
Capabilities that keep your premises compliant and ready for inspection.
BS 8214:2026 methodology
Every leaf inspected against the current code of practice, covering leaf, frame, seals, hinges, closers, locks, glazing and signage.
Gaps, seals & closers checked
Leaf-to-frame gaps measured, intumescent and smoke seals verified, self-closing function tested from a range of openings.
Photographic report
Each door photographed with a pass/fail and a clear note of any defect, so the record stands up to inspector and insurer scrutiny.
Prioritised action plan
Defects graded by severity with a recommended action and timescale — replace, repair or monitor — and a costed remedial option.
Remedial works
Seals, hinges, closers and signage replaced on site where a repair is possible, with full leaf replacement scheduled where the door has failed beyond repair.
Re-inspection schedule
Annual or six-monthly re-inspection intervals set against your risk and building type, with reminders ahead of each review.
Standards & compliance.
Every system is specified, installed and maintained to current British Standards and legislation, with documented evidence your responsible person can hand to inspectors and insurers with confidence.
BS 8214:2026
Fire door assemblies — code of practice.
BS 476-22 / BS EN 1634-1
Fire resistance of doorsets.
RRFSO 2005
Statutory duty for compartmentation.
Who we serve.
We deliver fire door inspections for commercial, industrial, education, healthcare and residential premises across Norfolk, Suffolk and Cambridgeshire.
Frequently asked questions
Common questions about fire door inspections.
How often should fire doors be inspected?
BS 8214 and the fire safety order expect a regular, documented inspection. Best practice is at least every six months for higher-risk premises such as high-rise residential and annually for lower-risk buildings, with additional checks after any damage or alteration.
What does a fire door inspection cover?
The leaf, frame, intumescent and smoke seals, hinges, self-closer, locks and latches, glazing, hold-open devices and signage. Every item is checked against BS 8214:2026 and recorded with a pass or a defect.
Can you carry out the remedial works as well?
Yes. Where a door can be brought back to standard we replace seals, hinges, closers and signage on site. Where a leaf has failed beyond repair we schedule a full doorset replacement with a documented trail.
Is a fire door inspection a legal requirement?
The responsible person has a duty to maintain compartmentation under the RRFSO, and post-Grenfell scrutiny means a documented, competent inspection is the evidence expected. We provide that record on every leaf.
One Check Fire
More fire safety services from One Check.
One Check Fire
Talk to our fire team.
Tell us about your premises and what you need. We will confirm scope, compliance requirements and response times, then arrange a survey at a time that suits your building.