One Check Fire — Detection
Fire Detection & Alarm Systems
Detection engineered to your building's risk profile and layout, from conventional panels to networked addressable systems on complex sites.
Back to One Check Fire
Overview
Design, installation and commissioning of detection and alarm systems tailored to your premises, from conventional panels to networked addressable systems on complex sites. Every system is set up to behave predictably during an incident and to keep your responsible person audit-ready.
Our engineers work to BS 5839-1, the recognised British Standard for fire detection and alarm systems in buildings. We survey the risk, specify the right category of system, agree the cause and effect logic up front, and commission against a documented test schedule — so your system passes first time and behaves the way you, your insurers and the fire and rescue service expect during an incident.
What we do
Capabilities that keep your premises compliant and ready for inspection.
Conventional & addressable panels
From single-panel conventional systems to multi-loop addressable panels that pinpoint the device in alarm, sized to your building and risk.
Networked multi-site systems
Panels networked across large or multi-building estates with a single head-end, shared graphics and zoned evacuation control.
Cause & effect programming
Detection inputs mapped to outputs — sounders, visual alarms, door release, lift recall, AHU shutdown and gas isolation — agreed and documented before commissioning.
Monitor-ready & scalable
Systems designed from day one for connection to an approved monitoring centre, with capacity for expansion as your building changes.
BS 5839-1 commissioning
Full commissioning to BS 5839-1 with a documented test schedule, certificates and a handover pack for your responsible person.
Planned maintenance
Quarterly, six-monthly and annual servicing to keep your system compliant, with records kept on site for inspection.
Standards & compliance.
Every system is specified, installed and maintained to current British Standards and legislation, with documented evidence your responsible person can hand to inspectors and insurers with confidence.
BS 5839-1
Fire detection and alarm systems for buildings.
BS 5839-6
Domestic detection and alarm guidance.
EN54
Component standard for detectors, panels and sounders.
Who we serve.
We deliver fire detection & alarm systems for commercial, industrial, education, healthcare and residential premises across Norfolk, Suffolk and Cambridgeshire.
Frequently asked questions
Common questions about fire detection & alarm systems.
What category of fire alarm system do I need?
It depends on the building use, occupancy and risk. We carry out a fire alarm design assessment to BS 5839-1 and recommend the appropriate category — L1 to L5 for life protection, P1 to P2 for property protection — before any equipment is specified.
Do you install addressable or conventional systems?
Both. We specify addressable systems where precise location of an alarm matters and on larger or more complex sites, and conventional systems where the building layout suits a simpler, cost-effective approach. The decision is driven by your risk assessment and building, not by a preferred product.
Can you connect the system to a monitoring centre?
Yes. Every system we install is designed to be monitor-ready, and can be connected to an approved alarm receiving centre (ARC) for automatic fire and rescue service alerting on unoccupied or high-risk premises.
How often must a fire alarm be serviced?
BS 5839-1 requires inspection and test at least every six months, with many premises opting for quarterly visits. We provide planned maintenance contracts with reminders and on-site records so the system stays compliant.
One Check Fire
More fire safety services from One Check.
One Check Fire
Talk to our fire team.
Tell us about your premises and what you need. We will confirm scope, compliance requirements and response times, then arrange a survey at a time that suits your building.