Norfolk Fire Group is now ONE CHECK SERVICES™

Security & Fire Systems Compliance Guide

What keeps your protection systems compliant.

A practical walk-through of the inspections, tests and certificates most commercial premises need across security and fire systems — from intruder alarms, CCTV and access control to fire alarms, extinguishers, kitchen suppression and emergency lighting.

Intruder · CCTV · Access Control · Fire Alarm

Extinguishers · Suppression · Emergency Lighting

Norfolk · Suffolk · Cambridgeshire

01

Intruder Alarms

BS EN 50131 / PD 6662 / BS 8243

Grade-matched design, installation and quarterly to annual maintenance. Remote signalling via an approved ARC keeps police and keyholder response on track and satisfies insurer requirements.

  • Grade & risk assessment
  • Panel & device servicing
  • ARC signalling test
  • Logbook & causes of activation
02

CCTV Systems

BS 6267 / BS EN 62676 / Surveillance Commissioner Code

Coverage, image quality, retention and privacy by design. We review camera placement, storage, signage and data subject access so footage is admissible and the system stays lawful.

  • Coverage & resolution review
  • Storage & retention period
  • Privacy & signage compliance
  • Remote access security
03

Access Control

BS EN 60839-11 / BS EN 50133

Credential management, audit trails and fail-safe release tied to the fire alarm. We check who can go where, that doors release on alarm, and that logs support your safeguarding obligations.

  • Credential & privilege audit
  • Fire alarm fail-safe release
  • Anti-tailback & door forcing
  • Event log retention
04

Fire Alarm Systems

BS 5839-1 / BS 5839-6

Category, zone and detector coverage reviewed against the building layout. Six-monthly routine servicing, annual cause-and-effect validation and a clear logbook keep the system audit-ready.

  • Category & coverage check
  • Detector & call point test
  • Quarterly / six-monthly service
  • Logbook & non-conformities
05

Fire Extinguishers

BS 5306-3 / BS 5306-8

Correct class, rating and positioning for the risks present. Basic annual service, extended service and replacement schedule, with servicing labels and a site register kept up to date.

  • Class & siting review
  • Annual basic service
  • Extended service due date
  • Servicing labels & register
06

Kitchen Fire Suppression

LPS 1223 / EN 13565 / EN 1146

Commercial hood, duct and appliance suppression that discharges in seconds and shuts off fuel. Six-monthly service is standard, with nozzles, fusible links and discharge heads inspected and replaced.

  • Nozzle & pipe inspection
  • Fusible link replacement
  • Fuel shut-off test
  • Discharge head & cartridge check
07

Emergency Lighting

BS 5266-1 / BS EN 50172

Illuminance, duration and test routine on every escape route and final exit. Monthly flick tests and a full three-hour annual discharge, with results logged and defective units rectified.

  • Lux & duration check
  • Monthly flick test
  • Annual full discharge
  • Test log & defect log
08

Mechanical & Physical Security

BS EN 12209 / BS 8220 / PAS 24

Locks, hinges, safes, shutters and physical barriers that back up the electronic systems. We survey doors, frames and glazing and confirm they meet the grade your risk assessment calls for.

  • Door & frame integrity
  • Lock & hinge grade
  • Physical barrier review
  • Insurance & specifier compliance

Staying audit-ready

Why inspections and certificates matter.

Security and fire systems are only effective if they work when called upon. The British Standards set out how each one must be installed, serviced and tested, and insurers, enforcing authorities and auditors expect evidence that the work has been done. Keeping a clear service logbook and certificate set for every system is what turns a fit-out into an ongoing, defensible compliance record.

  • One service logbook per system
  • Certificates retained for inspection
  • Review dates and intervals set
  • Defects logged and rectified

How often should each system be serviced?

There is no single interval — each system has its own standard. The table shows the typical minimum for the most common commercial systems.

Quarterly to six-monthly

Fire alarm, kitchen suppression, ARC signalling test.

Six to twelve months

Intruder alarm, CCTV, access control, extinguishers.

Monthly plus annual

Emergency lighting flick test and full discharge.

Risk-based scheduling

We set service intervals around the grade and risk of each system, not a generic calendar, so higher-risk equipment gets the attention it needs.

One compliance record

Every system's certificates, service reports and test logs held in one place, ready for insurers, auditors and the enforcing authority.

Defects rectified fast

Faults logged on the visit and quoted the same week, so a failed detector or broken camera never drifts past its next service.

Book a systems review

Book a security & fire systems review.